Problem cause solution communications / dial-out – Vintage Cellars FGD-0400 User Manual
Page 120

Sensaphone
®
Model 400 User’s Manual
117
Problem
Cause
Solution
Communications
/ Dial-out:
2.
The
Model
400
will
not
answer
the
telephone
when
called
for
a
Status
Report
or
alarm
acknowledgment.
e)
The
Model
400
is
connected
to
an
incom
-
patible
telephone
line.
a)
Rings
Until Answer
is
incorrectly
pro
-
grammed.
b)
The
Model
400
is
connected
to
an
incom
-
patible
telephone
line.
The
Model
400
must
be
connected
to
a
standard
(2-wire
analog)
telephone
line,
not
a
digital
extension
to
a
phone
system.
If
the
unit
will
not
dial
out
and
the
factors
previously
listed
have
been
ruled
out,
try
connecting
the
unit
to
a
standard
residential
telephone
line.
Recheck
programming
of
Rings
Until
Answer.
Refer
to
Chapter
4,
Section
4.5.1.
Some
telephone
systems
will
not
allow
the
telephone
to
ring
beyond
4
rings.
If
your
Model
400’s
Rings
Until
Answer
is
set
at
more
than
4
rings,
you
may
not
be
able
to
access
the
unit.
Try
setting
the
Rings
Until
Answer
to
less
than
4
rings.
If
this
does
not
correct
the
problem,
it
may
indicate
telephone
line
incompatibility.
In
this
case,
try
connecting
the
Model
400
to
a
standard,
residential
telephone
line.