2 led annunicators, 3 indicator operations, Led annunicators – Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual
Page 9: Indicator operations

CLS-420 Installation Manual
5
1.3.2
LED Annunicators
The 420 display uses a set of six LED annunicators to provide additional information about the value being
displayed:
•
Gross
and
Net
annunciators are lit to show whether the displayed weight is a gross or net weight.
•
Center of zero (
): Gross weight is within 0.25 graduations of zero. This annunciator lights when the
scale is zeroed.
•
Standstill (
): Scale is at standstill or within the specified motion band. Some operations, including tare
functions and printing, can only be done when the standstill symbol is shown.
•
lb
and
kg
annunciators indicate the units associated with the displayed value: lb=pounds, kg=kilograms.
The displayed units can also be set to short tons (tn), metric tons (t), ounces (oz), grams (g), or NONE (no
units information displayed). The
lb
and
kg
LEDs function as primary and secondary units annunciators for
some combinations of primary and secondary units. If neither primary nor secondary units are lb or kg the
lb
annunciator is lit for primary units,
kg
for secondary units.
1-1 shows which annunciators are used for all combinations of configured primary and secondary units. For
example:
•
If the primary unit is pounds (lb) and the secondary unit is kilograms (kg), the
lb
LED is lit for primary
units,
kg
for secondary units.
•
If the primary unit is pounds (lb) and the secondary unit is short tons (tn), the
lb
LED is lit for primary
units,
kg
for secondary units. There is not an LED for short tons, so the
kg
LED is used as the secondary
units annunciator.
•
If the primary unit is short tons (tn) and the secondary unit is pounds (lb), the
lb
LED is lit for primary units
(tn), and
kg
is lit for secondary units (lb). Because there is no LED for short tons, the
lb
and
kg
LEDs are
used as primary and secondary units annunciators.
Table 1-1. Units Annunciators, Showing Primary / Secondary LEDs Used for All Configurations
Primary Unit
Secondary Unit
lb
kg
oz
g
tn
t
none
lb
lb / lb
lb / kg
lb / oz
lb / g
lb / kg
kg
kg / lb
kg / kg
kg / oz
kg / g
lb / kg
oz
oz / lb
oz / kg
oz / oz
oz / g
oz / kg
g
g / lb
g / kg
g / oz
g / g
g / kg
tn
lb / kg
lb / kg
lb / oz
lb / g
lb / lb
lb / kg
lb / kg
t
lb / kg
lb / lb
lb / kg
none
lb / kg
lb / kg
lb / lb
1.3.3
Indicator Operations
Basic 420 operations are summarized below.
Toggle Gross/Net Mode
Press the
GROSS/NET
key to switch the display mode from gross to net, or from net to gross. If a tare value has been
entered or acquired, the net value is the gross weight minus the tare.
Gross mode is shown by the
Gross
annunciator; net mode is shown by the
Net
annunciator.
Toggle Units
Press the
UNITS
key to switch between primary and secondary units. The appropriate units LED under the display
is lit.
Zero Scale
1. In gross mode, remove all weight from the scale and wait for the standstill annunciator (
).
2. Press the
ZERO
key. The center of zero (
) annunciator lights to indicate the scale is zeroed.