0 appendix, 1 error messages, 1 displayed error messages – Rice Lake CLS-420 Cargo Lift Scale Installation Manual User Manual
Page 50: Appendix, Displayed error messages

40
CLS-420 Installation Manual
8.0 Appendix
8.1
Error Messages
The 420 indicator provides a number of error messages. When an error occurs, the message is shown on the
indicator LED display.
8.1.1
Displayed Error Messages
The 420 provides a number of front panel error messages to assist in problem diagnosis. Table 8-1 lists these
messages and their meanings.
Table 8-1.
420
Error Messages
Error Message
Description
Solution
E A/D
A/D physical error
Call Rice Lake Weighing Systems (RLWS) Service.
EEEROM
EEPROM physical error
EVIREE
Virgin EEPROM
Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells.
EPCKSM
Parameter checksum error
EACKSM
A/D calibration checksum error
A/D converter requires recalibration. Call RLWS Service.
EFCKSM
Printer format checksum error
Call RLWS Service.
ELCKSM
Load cell calibration checksum error
Recalibrate load cells.
EIDATA
Internal RAM checksum error
Call RLWS Service.
E REF
A/D reference error
A/D converter requires recalibration. Call RLWS Service.
ERROR
Internal program error
Check configuration. Run XE command (see Section
Call RLWS Service if unable to clear error by cycling power or if error
recurs.
OVERFL
Overflow error
Weight value too large to be displayed.
------
Gross > overload limit
Gross value exceeds overload limit. Check configuration or signal
input level. Overload can be caused by input signal > 45 mV or
common mode voltage > 950 mV.
______
A/D underrange
A/D reading < –4 mV. Check scale for binding or damage.
RNGERR
GRADS > 100,000
WVAL > 100,000
Only shows up in Config mode.
NO COM
No communication with j-box
Check the cable or wireless connections or install a charged battery.
ERRSS
Serial Scale Error
Generic error. Need to troubleshoot system or call RLWS service.
----
Forks not level
Position forks within three degrees of level.
Wait
J-Box is powering up
This display is a normal action of the indicator.
LowBat
J-Box battery is getting low or dead.
May not occur if completely dead.
Change battery.
ErrCell
J-Box is reporting a generic error
This is a declared error and should look at test mode to diagnose the
problem.