38
CLS-420 Installation Manual
6.0
Calibration
Note
While the functionality remains the same for a standard 420 digital weight indicator, there are certain menu
choices that need to be changed in the manual that are specific to the proper functioning of the CLS-Series
Cargo Lift Scale which include Calibration, Serial, Program, and Print Format.
The CLS-420 indicator can be calibrated using the front panel calibration procedure as explained in Section
6.1.
This method consists of the following steps:
•
Zeroing the scale inclinometer
•
Zero calibration
•
Entering the test weight value
•
Calibration of cell #1
•
Calibration of cell #2
The following sections describe the calibration procedure for each of the calibration methods.
9999999
9999999
9999999
9999999
"/(-&;
87"-
$.$&-
"-(065
%*(*/
4&51/5
130(3.
1'03.5
4&3*"-
$"-*#3
$0/'*(
'03."5
$.$&-
7&34
$.;&30
Figure 6-1. CLS-420 Calibration (CALIBR) Menu
6.1
Front Panel Calibration
To calibrate the indicator, the forklift tines must be in place as test weights are placed upon them.
Note
Use a level to ensure that the forklift tines are level prior to calibration.
The test weight used to calibrate the CLS-420 cannot be greater than 2500 lbs.
To calibrate the indicator using the front panel, do the following:
1. Place the 420 indicator in setup mode (display reads
CONFIG
).
2. Press until the display reads
CALIBR
(see Figure
3. Use a level to level the forklift tines before pressing to go to
ANGLEZ
.
4. With
ANGLEZ
displayed and no weight on the forklift, press
to zero the scale inclinometer.
-CAL-
is
briefly displayed on the indicator.
5. With
CMZERO
displayed press
to capture the lead load zero.
-CAL-
is displayed briefly on the indicator.
6. The indicator then asks for the
WVAL
(weight value). Enter the weight of the test weight to be used in the
calibration procedure by pressing the enter key
and then keying in the weight value using the numeric
keypad. Then press enter again.
7.
CMCEL1
is displayed.
8. Put the test weight on the left tine of the forklift
&/2+,)&4
,//+).'
,%&4
and press
.
-CAL-
is briefly displayed.
9. Once
-CAL-
is displayed, the indicator display automatically jumps to
CMCEL2
. Move test weight to the
other tine. Press
and
-CAL-
is briefly displayed.
10. At this time the display says
-PASS-
or
-FAIL-
. If the display says
PASS
, it is followed by
CALIBR
and the
calibration procedure is complete.
11. If the display says
-FAIL-
, then the display goes back to
CMZERO
and the calibration procedure must be
started over.