3 calibration menu, Calibration menu – Rice Lake Intrinsically Safe User Manual
Page 31

320IS Installation Manual - Configuration
25
3.3.3
Calibration Menu
Figure 3-3. Calibration Menu
UNITS
LB
KG
OZ
TN
T
G
NONE
Specifies primary unit for displayed and printed weight. Values are: LB=pound;
KG=kilogram; OZ=ounce; G=gram; TN=short ton; T=metric ton. Selecting NONE, removes
the primary units from print.
Secondary Units
UNITS
KG
OZ
TN
T
G
NONE
LB
Specifies secondary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; OZ=ounce; G=gram; TN=short ton; T=metric ton. An arbitrary unit may be
used by selecting NONE and specifying a multiplier set under MULT.
MULT
1.00000
number
If a unit other than the presets is to be used, an arbitrary unit may be selected for conversion
to a desired unit. The value entered here is applied as a multiplier to the primary unit - or to
the calibration unit if the primary unit is set to OFF. If the primary unit is changed after setting
this value, the multiplier will also change. Only the first six significant (non-zero) digits of the
set value are stored.
CALIBR Menu
Parameter
Choices
Description
Level 2 submenus
WZERO
—
Display and edit the zero calibration A/D count value.
DO NOT adjust this value after WSPAN has been set!
WVAL
—
Display and edit the test weight value.
WSPAN
—
Display and edit the span calibration A/D count value.
REZERO
—
Press ENTER to remove an offset value from the zero and span calibrations.
Use this parameter only after WZERO and WSPAN have been set. See Section 4.1 on
page 33 for more information about using this parameter.
Table 3-4. Calibration Menu Parameters
FORMAT Menu
Parameter
Choices
Description
Table 3-3. Format Menu Parameters (Continued)
WZERO
*CAL*
Display and edit
zero calibration
A/D count value
Display and edit
test weight value
WVAL
*CAL*
Display and edit
span calibration
A/D count value
WSPAN
*
CAL*
Press Enter to
remove offset from
zero and span
calibrations
REZERO
XXXXXXX
XXXXXXX
XXXXXXX
XXXXXXX
ALGOUT
DIG IN
PROGRM
PFORMT
SERIAL
CALIBR
CONFIG
FORMAT
XXXXXXX
SETPNT