background image

KTD-N0861-B

Page 6

System Specification


KTA75/Flex Users Guide

KTA70M/mITX Users Guide


Environmental Operating:

0°C – 60°C operating temperature (forced cooling). It is the customer’s responsibility to

provide sufficient airflow around each of the components to keep them within allowed
temperature range.

10% - 90% relative humidity (non-condensing)

Storage:
-20°C – 70°C; lower limit of storage temperature is defined by specification restriction of

on-board CR2032 battery. Board with battery has been verified for storage temperature
down to -40°C by Kontron.

5% - 95% relative humidity (non-condensing)

Electro Static Discharge (ESD) / Radiated Emissions (EMI):
All Peripheral interfaces intended for connection to external equipment are ESD/ EMI

protected.
EN 61000-4-2:2000 ESD Immunity

EN55022:1998 class B Generic Emission Standard.


Safety:

EN 60950-1: 2006/ A11:2009/ A1:2010/A12:2011
IEC 60950-1(ed.2)

CSA C22.2 No. 60950-1

Product Category: Information Technology Equipment Including Electrical Business
Equipment

Product Category CCN: NWGQ2, NWGQ8
File number: E194252 ( E194252-A21-CB-1)


Theoretical MTBF:

314.614 / 153.436 hours @ 40ºC / 60ºC


Restriction of Hazardous Substances (RoHS):

All boards in the KTA75 family are RoHS/RoHS-II compliant.

Capacitor utilization:

No Tantalum capacitors on board
Only Japanese brand Solid capacitors rated for 100 ºC used on board