Command syntax netbootloader, Sq (non-amc / smp) – Kontron NetBootLoader User Manual
Page 82

ID 1022-8317, Rev. 2.0
Command Syntax
NetBootLoader
Page 74
SQ
(NON-AMC / SMP)
FUNCTION:
Set or display the boot sequence
SYNTAX:
sq [
where:
sq
command
parameter: numeric string: “0, 1, 2, 3”
ID number of image to be booted
parameter: numeric string: “0, 1, 2, 3”
ID number of image to be booted
parameter: numeric string: “0, 1, 2, 3”
ID number of image to be booted
parameter: numeric string: “0, 1, 2, 3”
ID number of image to be booted
DESCRIPTION:
Up to four bootable images may be programmed into the NBL Flash
memory. The boot sequence defines to the NetBootLoader the order
in which images are to be accessed when booting. The
NetBootLoader starts with “
image is found. In the case that a valid image is not found, the
NetBootLoader stops searching and waits for operator intervention.
All four number parameters must be defined even if there is not an
image in the NBL Flash memory with that ID number.
Any given ID number may only be used once: e.g. a sequence of
0120 is not permitted.
The default sequence is 0123 if the boot sequence has not been
programmed.
USAGE:
Display the current boot sequence setting.
COMMAND / RESPONSE:
sq
Bootsequence: 0 - 3 - 1 - 2
Set the boot sequence to 3201.
COMMAND / RESPONSE(none):
sq 3201