beautypg.com

Command syntax netbootloader – Kontron NetBootLoader User Manual

Page 70

background image

ID 1022-8317, Rev. 2.0

Command Syntax

NetBootLoader

Page 62

DESCRIPTION:

To set or display the operational parameters for the serial interfaces
the command PF is used.

At startup the settings for the primary and the secondary interfaces
are always set to the default values (9600/8/n/1). This is to avoid a
possible system lockout. If other settings are required during opera-
tion of the NetBootLoader they may be made. If changes are made, it
must be ensured that corresponding parameters are used for the op-
erator console.

Issuing this command without parameters being specified will display
the current serial port settings.

Syntax-wise, no spaces are permitted between the parameters and
they must be separated with a slash. Not all parameters must be
specified, but the “/” characters must be present to distinguish the
different parameters from each other. The sequence can be aborted
after every option.

USAGE:

Set “term” to 300 Baud, 7 Bits/char, odd parity, and 2 stop bits

COMMAND / RESPONSE (none):

pf term 300/7/o/2

Set the bits per character parameter of SER0 to 7

COMMAND / RESPONSE (none):

pf ser0 //7

Set the stop bits parameter of SER0 to 2

COMMAND / RESPONSE (none):

pf ser0 ///2

PF