A.2 hpm jumpers, A.3 standard i/o module jumpers – Compaq GS160 User Manual
Page 174

A-2
AlphaServer GS80/160/320 User's Guide
A.2
HPM Jumpers
Table A–2 lists hierarchical switch power manager (HPM) jumpers and
their functions. The HPM module has three 2-position jumpers, none of
which are normally installed.
Table A–2 HPM Jumpers
Jumper
Function, When Installed
J2
Flash_Write_Inhibit. Prevents the hardware from writing to
flash memory.
J3
Force_FSL. Causes the firmware to remain in the fail-safe
loader code after HPM reset.
J4
HS_CSB_ID0. Sets ID0 of the microprocessor’s CSB address
field to a 1.
A.3
Standard I/O Module Jumpers
Table A–3 lists standard I/O module jumpers and their functions. The
jumper station is three-pronged and the installed position is indicated
by a silkscreen connection.
Table A–3 Standard I/O Module Jumpers
Jumper
Function, When Installed
J12
Forces SRM console defaults.
J13
Forces COM1 bypass.
J17
SCM remains in fail-safe loader code upon reset.
J18
Forces the SCM defaults.