beautypg.com

A.2 hpm jumpers, A.3 standard i/o module jumpers – Compaq GS160 User Manual

Page 174

background image

A-2

AlphaServer GS80/160/320 User's Guide

A.2

HPM Jumpers

Table A–2 lists hierarchical switch power manager (HPM) jumpers and
their functions. The HPM module has three 2-position jumpers, none of
which are normally installed.

Table A–2 HPM Jumpers

Jumper

Function, When Installed

J2

Flash_Write_Inhibit. Prevents the hardware from writing to
flash memory.

J3

Force_FSL. Causes the firmware to remain in the fail-safe
loader code after HPM reset.

J4

HS_CSB_ID0. Sets ID0 of the microprocessor’s CSB address
field to a 1.

A.3

Standard I/O Module Jumpers

Table A–3 lists standard I/O module jumpers and their functions. The
jumper station is three-pronged and the installed position is indicated
by a silkscreen connection.

Table A–3 Standard I/O Module Jumpers

Jumper

Function, When Installed

J12

Forces SRM console defaults.

J13

Forces COM1 bypass.

J17

SCM remains in fail-safe loader code upon reset.

J18

Forces the SCM defaults.