beautypg.com

Compaq GS160 User Manual

Page 164

background image

8-24

AlphaServer GS80/160/320 User’s Guide

8.7.5

Configuring Remote Dial-In

Before you can dial in through the SCM modem port or enable the
system to call out in response to system alerts, you must configure the
system for remote dial-in.

Example 8–1 Dial-In Configuration

SCM_E0> enable remote

SCM_E0> set password wffirmware

SCM_E0> set init ate0v0&c1s0=2

SCM_E0> init

Querying the modem port...modem detected
Initializing modem...passed
Modem port initialized

SCM_E0>

NOTE: The following modems require the initialization strings shown here.

For other modems, see your modem documentation.

Modem

Initialization String

Compaq Microcom 510 (North America)

Ate0v0&c1s0=2

3Com U. S. Robotics Courier
V.Everything/56K (North America and Japan)

Ate0v0&c1s0=2

Hayes Accura (North America)

Ate0v0&c1&k3s0=2

AIWA PV-BW5610 56K V.90 & K56flex
Data/Fax Modem (Japan)

Ate0v0&c1s0=2

OMRON ME5614D (Japan)

Ate0v0&c1s0=2

MultiTech MT5600ZDX (North America)
MultiTech MT5600ZDXe (Europe)

Ate0v0&c1s0=2