Series 8750XD Unitized Curtain Wall Installation Instructions

Note:
Bolt size and type specified in the
approved shop drawing must be used.

Section 5 - Intermediate Floor Slab Anchor Installation

Figure 41

1. Set the slab anchors into the opening inserting anchor bolts into the slots in the approximate locations required. Do not use shims between the slab anchor

and the slab. Use bituminous coating or other appropriate primer to separate slab anchor from substrate. Anchors are typically located at the mullion center
line at intermediate locations. Jamb anchor locations vary. Refer to the approved final shop drawings for location.

2. Apply flat and lock washers and the serrated washers onto the anchor bolts. Turn the serrated washer so that the teeth don't interlock to simplify anchor

adjustments. Leave the nuts loose enough to allow free movement of the anchor assembly. Once the units are set, and final adjustments are made, turn the
serrated washers so that the teeth interlock and secure the anchor assembly.

3. Refer to the final approved shop drawings or supplemental installation instructions for more information.

Figure 43

Turn the serrated washer so that
the teeth don't interlock to
simplify anchor adjustments.

Anchor bolts as

required.

FM56 or FM60
Serrated Washers

FM61 Slab

Anchor

Figure 44

Figure 42

FM63 Slab

Anchor

FM62 Slab

Anchor

Once the units are set, and final
adjustments are made, turn the
washer so that the teeth interlock
and secure anchor bolts.

FM61 Slab

Anchor

FM61 Slab