Subsill installa on – EFCO Special Purpose Windows Installation User Manual

Page 41

background image

 

EFCO 2014 

 

Window Installation Instructions - Typical Subframe Installation Section

 Locate and install the subsill as shown on the shop       

drawings. 

 Note: The sealing of the subsill to the condiƟon is criƟcal to

the performance of the assembly and will vary greatly
based on the building condiƟon. The locaƟon of these seals
will be shown on the shop drawings.

 For perimeter anchor type and spacing, refer to the        

approved shop drawings or consult the project design    
professional.  All anchorage clear holes, blocking, sealant 
and perimeter fasteners are not by EFCO. 

 It is cri cal that subsills are installed level and true for the 

best water performance. 

 Remove all debris from the subsill and cover all fastener 

heads with sealant to ensure water  ght seal.  Tool the 
sealant around the fastener heads so that the sealant 
makes contact with the face of the subsill. 

 Before installing subjambs run a bead of sealant around the 

inside of the end dam and shown.  This will help to ensure a 
good seal between the subsill and subjamb.  Complete this 
step just prior to installing the subjamb otherwise the    
sealant will skim and not  create an adequate seal. 

Subsill Installa on 

Field drilled anchorage  
clear hole 

Fastener per shop drawings 
(not by EFCO) 

Seal over fastener 
head and tool down 
to subsill face 

Sealant before 
se ng subjambs 
(don’t allow to skim)