Salter Brecknell SBI140 User Manual
Page 33

28
P14.x
0, 1, 2
2
Weight signal within power-on zero
point range, Choose which data as
current power-on zero point; 0= current
weight ; 1= calibration zero-point;
2=switch-off zero-point
P15.x
0, 1, 2
1
Weight signal not within power-on zero
point range, Choose which data as
current power-on zero point; 0=
current weight ;
1=
calibration
zero-point
;
2=switch-off
zero-point;
3=continuously display “0ˉˉˉˉ”
P16.x
0, 1, 2, 3,
4, 5, 6,7,8
8
Zero tracking range: 0=0d, no tracking;
1=+0.25d; 2= +0.5d; 3=+1d; 4=+1.5d;
5=+2d; 6=+3d; 7= +4d;
8=+5d
P17.x
0, 1, 2, 3
2
Data filter intensity: 0=very weak,
1=weak, 2=middle
, 3=strong
P18.x
0, 1….9
1
Check
weight stability
range:
0=+0.5d; 1= ± 1d
; 2=+1.5d;
3=+2d; 4=+3d; 5=+4d ; 6=+5d ; 7=+6d ;
8=+7d; 9=+8d
P19.x
0, 1….9
1
Overload
limit
range:
0=FS+0d;
1=FS+9d;
2=101%FS;
3=102%FS;
4=105%FS; 5=110%FS; 6=120%FS;
7=150%FS; 8=200%FS; 9=No limitation
P20.x
0,1,2
2
Backlight on-off mode:
0= Backlight is always off;
1= Backlight is always on;
2= Backlight is auto on and auto off
. It is
auto off after 10s when scale goes to
stable and has no key operation, and it is
auto on when scale is unstable or there’s
some key operation.