beautypg.com

Salter Brecknell SBI140 User Manual

Page 33

background image

28

P14.x

0, 1, 2

2

Weight signal within power-on zero
point range, Choose which data as
current power-on zero point; 0= current
weight ; 1= calibration zero-point;
2=switch-off zero-point

P15.x

0, 1, 2

1

Weight signal not within power-on zero
point range, Choose which data as
current power-on zero point; 0=
current weight ;

1=

calibration

zero-point

;

2=switch-off

zero-point;

3=continuously display “0ˉˉˉˉ”

P16.x

0, 1, 2, 3,

4, 5, 6,7,8

8

Zero tracking range: 0=0d, no tracking;
1=+0.25d; 2= +0.5d; 3=+1d; 4=+1.5d;
5=+2d; 6=+3d; 7= +4d;

8=+5d

P17.x

0, 1, 2, 3

2

Data filter intensity: 0=very weak,
1=weak, 2=middle

, 3=strong

P18.x

0, 1….9

1

Check

weight stability

range:

0=+0.5d; 1= ± 1d

; 2=+1.5d;

3=+2d; 4=+3d; 5=+4d ; 6=+5d ; 7=+6d ;
8=+7d; 9=+8d

P19.x

0, 1….9

1

Overload

limit

range:

0=FS+0d;

1=FS+9d;

2=101%FS;

3=102%FS;

4=105%FS; 5=110%FS; 6=120%FS;
7=150%FS; 8=200%FS; 9=No limitation

P20.x

0,1,2

2

Backlight on-off mode:
0= Backlight is always off;
1= Backlight is always on;
2= Backlight is auto on and auto off

. It is

auto off after 10s when scale goes to
stable and has no key operation, and it is
auto on when scale is unstable or there’s
some key operation.