beautypg.com

Salter Brecknell SBI140 User Manual

Page 20

background image

15

0.2 lb

0.1 kg

0.2 lb

5 oz

2 lb

1 kg

2 lb

Not available

20 lb

10 kg

20 lb

Not available

0.0005 lb

0.0002 kg

0.0005 lb

Not available

0.005 lb

0.002 kg

0.005 lb

0.1 oz

0.05 lb

0.02 kg

0.05 lb

1 oz

0.5 lb

0.2 kg

0.5 lb

Not available

5 lb

2 kg

5 lb

Not available

50 lb

20 kg

50 lb

Not available

5.11) P11.x: select the weighing unit that may be chosen by pressing UNIT

x = 0 : only kg

x = 1 : only lb

x = 2 : only lb: oz

x = 3 : kg or lb

x = 4 : kg or lb: oz

x = 5 : lb or lb: oz

x = 6 : kg, lb, or lb: oz

Above setting of units may not be available as per above tables in 5.10

5.12) P12.x: Power-on zero-point range

x = 0 : calibration zero point (CAL.P0) +1%FS

x = 1 : calibration zero point (CAL.P0) +2%FS

x = 2 : calibration zero point (CAL.P0) +5%FS

x = 3 : calibration zero point (CAL.P0) +10%FS

x = 4 : calibration zero point (CAL.P0) +20%FS

x = 5 : calibration zero point (CAL.P0) +50%FS

x = 6 : calibration zero point (CAL.P0) +100%FS

x = 7 : No limitation

5.13) P13.x: Zero range for ZERO button after switch on

x = 0 : Power-on zero-point ±1%FS;

x = 1 : Power-on zero-point ±2FS;

x = 2 : Power-on zero-point ±3%FS;

x = 3 : Power-on zero-point ±4%FS;

x = 4 : Power-on zero-point ±5%FS;