beautypg.com

Salter Brecknell SBI140 User Manual

Page 32

background image

27

P7.xy

00-31

13

Resolution select: 500,600,750,800,
1000,1200, 1500,2000,2400,2500, 3000,
3500, 4000, 5000

, 6000, 7000, 7500,

8000, 10000, 12000, 15000, 20000,
25000, 30000, 35000, 40000, 50000,
60000,70000,75000,80000,100000

P8.x

0,1, 2

0

Division select: 0=1

, 1=2, 2=5

P9.x

0,1,2,3,4,

5

0

Decimal point in calibration: 0= x1

, 1=

x0.1, 2= x0.01; 3= x0.001; 4= x0.0001;
5= x10

P10.x

0, 1

1

Calibration unit: 0=kg,

1=lb

P11.x

0, 1, 2, 3,

4, 5, 6

6

Weighing units enable: 0=only kg;
1=only lb; 2=only lb:oz; 3=kg or lb;
4=kg or lb:oz; 5=lb or lb:oz;

6=kg, lb, or

lb:oz

P12.x

0, 1, 2, 3,
4, 5, 6, 7,

3

Power-on zero-point range:
0=calibration zero -point +1%FS;
1=calibration zero -point +2%FS;
2=calibration zero-point +5%FS;

4=calibration zero-point +20%FS;

3=calibration zero-point +10%FS;

5=calibration zero-point +50%FS;
6=calibration zero-point +100%FS;
7=No limitation

P13.x

0,1….14

4

Zero range for ZERO button:
0= Power-on zero-point ±1%FS;
1= Power-on zero-point ±2FS;
2= Power-on zero-point ±3%FS;
3= Power-on zero-point ±4%FS;

5= Power-on zero-point ±10%FS;

4= Power-on zero-point ±5%FS;

6= Power-on zero-point ±20%FS;
7= No limitation
8= Power-on zero-point +1%FS
9= Power-on zero-point +2%FS
10=Power-on zero-point +3%FS
11=Power-on zero-point +4%FS
12=Power-on zero-point +5%FS
13=Power-on zero-point +10%FS
14=Power-on zero-point +20%FS