27
P7.xy
00-31
13
Resolution select: 500,600,750,800,
1000,1200, 1500,2000,2400,2500, 3000,
3500, 4000, 5000
, 6000, 7000, 7500,
8000, 10000, 12000, 15000, 20000,
25000, 30000, 35000, 40000, 50000,
60000,70000,75000,80000,100000
P8.x
0,1, 2
0
Division select: 0=1
, 1=2, 2=5
P9.x
0,1,2,3,4,
5
0
Decimal point in calibration: 0= x1
, 1=
x0.1, 2= x0.01; 3= x0.001; 4= x0.0001;
5= x10
P10.x
0, 1
1
Calibration unit: 0=kg,
1=lb
P11.x
0, 1, 2, 3,
4, 5, 6
6
Weighing units enable: 0=only kg;
1=only lb; 2=only lb:oz; 3=kg or lb;
4=kg or lb:oz; 5=lb or lb:oz;
6=kg, lb, or
lb:oz
P12.x
0, 1, 2, 3,
4, 5, 6, 7,
3
Power-on zero-point range:
0=calibration zero -point +1%FS;
1=calibration zero -point +2%FS;
2=calibration zero-point +5%FS;
4=calibration zero-point +20%FS;
3=calibration zero-point +10%FS;
5=calibration zero-point +50%FS;
6=calibration zero-point +100%FS;
7=No limitation
P13.x
0,1….14
4
Zero range for ZERO button:
0= Power-on zero-point ±1%FS;
1= Power-on zero-point ±2FS;
2= Power-on zero-point ±3%FS;
3= Power-on zero-point ±4%FS;
5= Power-on zero-point ±10%FS;
4= Power-on zero-point ±5%FS;
6= Power-on zero-point ±20%FS;
7= No limitation
8= Power-on zero-point +1%FS
9= Power-on zero-point +2%FS
10=Power-on zero-point +3%FS
11=Power-on zero-point +4%FS
12=Power-on zero-point +5%FS
13=Power-on zero-point +10%FS
14=Power-on zero-point +20%FS