Connunitseventtime, Connuniteventseverity, Connuniteventtype – Dell POWEREDGE M1000E User Manual
Page 242: Connuniteventobject, Connuniteventdescr
222
Fabric OS MIB Reference
53-1002750-01
Connectivity unit group
9
connUnitSEventTime
1.3.6.1.3.94.1.11.1.5
Read only
This is the sysuptime time stamp when the event occurred.
connUnitEventSeverity
1.3.6.1.3.94.1.11.1.6
Read only
The event severity level. The mapping between error log severity level
and this variable is:
Error log
FA-MIB
none (0)
unknown (1)
Critical (1)
critical (4)
Error (2)
error (5)
Warning (3)
warning (6)
Informational (4)
info (8)
Debug (5)
debug (9)
For more information about severity, refer to
in
connUnitEventType
1.3.6.1.3.94.1.11.1.7
Read only
The type of this event.
Possible values are:
•
unknown (1)
•
other (2)
•
status (3)
•
configuration (4)
•
topology (5)
Always set to 2 (other).
connUnitEventObject
1.3.6.1.3.94.1.11.1.8
Read only
This is used with the connUnitEventType to identify to which object the
event refers. It can be the OID of a connectivity unit or of another object,
like connUnitPortStatus.
Always set to null.
connUnitEventDescr
1.3.6.1.3.94.1.11.1.9
Read only
The description of the event.
Same as the string displayed in the system error log. The system error
log can be viewed using the errShow or errDump commands.
For Fabric OS v6.2.0 and later releases, the format of error messages
has changed. This field now uses the message title and number (for
example, WEBD-1006) and the message text. Previously, this field used
the task ID and all the message number and message text. For more
information on error messages, refer to Fabric OS Message Reference.
TABLE 75
Object and OID
Access
Description