Swfcporttype, Swfcportphystate, Swfcportopstatus – Dell POWEREDGE M1000E User Manual
Page 173: Swfcportadmstatus
Fabric OS MIB Reference
153
53-1002750-01
Fibre Channel port group
6
swFCPortType
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.2
Read only
The type of ASIC for the switch port.
Possible values are:
•
stitch (1)
•
flannel (2)
•
loom (3) (Brocade 2000 series)
•
bloom (4) (Valid value for Brocade 3250, 3850, 3900, 12000,
24000)
•
rdbloom (5)
•
wormhole (6)
•
other (7) (Valid value for Brocade 200E, 4012, 4100, 4900,
7500, 7600, 48000, 300, 5100 and 5300)
•
unknown (8)
swFCPortPhyState
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.3
Read only
The physical state of the port.
Possible values are:
•
noCard (1) - No card is present in this switch slot.
•
noTransceiver (2) - No Transceiver module in this port
(Transceiver is the generic name for GBIC, SFP, and so on).
•
laserFault (3) - The module is signaling a laser fault (defective
GBIC).
•
noLight (4) - The module is not receiving light.
•
noSync (5) - The module is receiving light but is out of sync.
•
inSync (6) - The module is receiving light and is in sync.
•
portFault (7) - The port is marked faulty (defective GBIC, cable, or
device).
•
diagFault (8) - The port failed diagnostics (defective G_Port or
FL_Port card or motherboard).
•
lockRef (9) - The port is locking to the reference signal.
•
validating (10) - The module is being validated.
•
invalidModule (11) - The module is invalid.
•
noSigDet (14) - No Signal is detected in the port.
•
unknown (255) - The module is unknown.
swFCPortOpStatus
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.4
Read only
The operational status of the port.
Possible values are:
•
unknown (0) - The port module is physically absent.
•
online (1) - User frames can be passed.
•
offline (2) - No user frames can be passed.
•
testing (3) - No user frames can be passed.
•
faulty (4) - The port module is physically faulty.
swFCPortAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.5
Read-write The desired state of the port. A management station might place the
port in a desired state by setting this object accordingly.
Based on the port status, this OID returns one of the following:
•
Online - When queried port is online.
•
Offline - When queried port is offline.
•
Faulty - When port is in faulty state.
The following values can be used to set this object:
•
Online - To change port's state to Online.
•
Offline - To change port's state to Offline.
TABLE 50
Object and OID
Access
Description