Dell PowerEdge R715 User Manual
Page 50

50
About Your System
Warning! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Warning!
Performance
degraded. CPU and
memory set to
minimum
frequencies to
meet PSU wattage.
System will
reboot.
The system configuration of
processor(s), memory
modules, and expansion
cards may not be supported
by the power supplies.
If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. If low wattage power
supplies are installed, replace
them with High Output
power supplies to use the
components. See "Power
Write fault.
Write fault on
selected drive.
Faulty USB device, USB
medium, optical drive
assembly, hard drive, or hard-
drive subsystem.
Replace the USB medium or
device. Ensure that the USB,
SAS backplane, or SATA
cables are properly
connected. See
Incorrect memory
configuration
CPU n.
The DIMM group for CPU n
is incorrectly configured and
caused the system to halt.
memory configuration
information. If the problem
persists, see
Message
Causes
Corrective Actions
book.book Page 50 Thursday, June 3, 2010 4:35 PM