Dell PowerEdge R715 User Manual
Page 25

About Your System
25
E1211 RAID
Controller
battery
failure.
Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "RAID
E1216 3.3 V
Regulator
failure.
Reseat PCIe
cards.
3.3 V voltage regulator
failed.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
E1219 Disk
Backplane
power
failure.
Check BP
power cable.
Storage backplane voltage
regulator failed.
Remove and reconnect
the backplane power
cable.
If the problem persists,
E122C CPU Power
Fault. Power
cycle AC.
A power fault was detected
when powering up the
processor(s).
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E122D Memory
Regulator #
Failed.
Reseat DIMMs.
One of the memory voltage
regulators failed.
Reseat the memory
modules. See
E122E On-board
regulator
failed. Call
support.
One of the on-board voltage
regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
Code
Text
Causes
Corrective Actions
book.book Page 25 Thursday, June 3, 2010 4:35 PM