Dell PowerEdge R715 User Manual
Page 28

28
About Your System
E1610 Power Supply
# (#### W)
missing.
Check power
supply.
Specified power supply
removed or is missing from
the system.
E1614 Power Supply
# (#### W)
error. Check
power supply.
Specified power supply
failed.
E1618 Predictive
failure on
Power Supply
# (#### W).
Check PSU.
A power supply fan failure,
an over-temperature
condition, or power supply
communication error caused
the predictive warning of an
impending power supply
failure.
E161C Power Supply
# (#### W)
lost AC
power. Check
PSU cables.
Specified power supply is
installed but lost its AC
input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
E1620 Power Supply
# (#### W) AC
power error.
Check PSU
cables.
Specified power supply's AC
input is outside the
allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
E1624 Lost power
supply
redundancy.
Check PSU
cables.
The power supply subsystem
is no longer redundant. If
the remaining power supply
fails, the system will shut
down.
Code
Text
Causes
Corrective Actions
book.book Page 28 Thursday, June 3, 2010 4:35 PM