Sas backplane, Removing the sas backplane – Dell PowerEdge R715 User Manual
Page 132
132
Installing System Components
SAS Backplane
Removing the SAS Backplane
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is
not covered by your warranty. Read and follow the safety instructions that
came with the product.
1 If installed, remove the front bezel. See "Removing the Front Bezel" on
2 Turn off the system and attached peripherals, and disconnect the system
from the electrical outlet.
3 Open the system. See "Opening the System" on page 78.
CAUTION:
To prevent damage to the drives and backplane, you must remove the
hard drives from the system before removing the backplane.
CAUTION:
You must note the number of each hard drive and temporarily label
them before removal so that you can replace them in the same locations.
4 Remove the cooling shroud. See "Removing the Cooling Shroud" on
5 Remove all hard drives. See "Removing a Hard-Drive Carrier" on page 82.
6 Disconnect the SAS data cable(s) and power cable from the backplane.
7 Push the blue release tabs in the direction of the arrows and slide the
backplane upwards.
8 Pull the backplane away from the system until the securing slots on the
backplane are free from the tabs on the front-chassis assembly.