Dell PowerEdge R715 User Manual
Page 24

24
About Your System
Table 1-1. LCD Status Messages
Code
Text
Causes
Corrective Actions
E1000 Failsafe
voltage
error.
Contact
support.
Check the system event log
for critical failure events.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1114 Ambient Temp
exceeds
allowed
range.
Ambient temperature
reached a point outside the
allowed range.
E1116 Memory
disabled,
temp above
range. Power
cycle AC.
Memory exceeded allowable
temperature and has been
disabled to prevent damage
to the components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
the problem persists, see
E1119 Chipset #
temp out of
range. Check
motherboard
heatsinks.
Chipset temperature
reached a point outside the
allowed range.
E1210 Motherboard
battery
failure.
Check
battery.
CMOS battery is missing or
the voltage is outside the
allowable range.
book.book Page 24 Thursday, June 3, 2010 4:35 PM