Troubleshooting system memory, Troubleshooting system, See "troubleshooting – Dell PowerEdge R715 User Manual
Page 157: System memory" on, E "troubleshooting system

Troubleshooting Your System
157
Troubleshooting System Memory
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is
not covered by your warranty. Read and follow the safety instructions that
came with the product.
NOTE:
Invalid memory configurations can cause your system to halt at startup
without video output. See "General Memory Module Installation Guidelines" on
page 92 and verify that your memory configuration complies with all applicable
guidelines.
1 If the system is operational, run the appropriate online diagnostic test.
See "Using Online Diagnostics" on page 169.
If diagnostics indicates a fault, follow the corrective actions provided by
the diagnostic program.
2 If the system is not operational, turn off the system and attached
peripherals, and unplug the system from the power source. Wait at least 10
seconds and then reconnect the system to power.
3 Turn on the system and attached peripherals and note the messages on
the screen.
Go to step 14 if an error message appears indicating a fault with a specific
memory module.
4 Enter the System Setup program and check the system memory setting.
See "Memory Settings Screen" on page 59. Make any changes to the
memory settings, if needed.
If the memory settings match the installed memory but a problem is still
indicated, go to step 14.
5 Turn off the system and attached peripherals, and disconnect the system
from the electrical outlet.
6 Open the system. See "Opening the System" on page 78.
7 If applicable, remove the cooling shroud. See "Removing the Cooling
8 Check the memory channels and ensure that they are populated correctly.
See "General Memory Module Installation Guidelines" on page 92.