Dell PowerEdge R715 User Manual
Page 34
34
About Your System
E2010 Memory not
detected.
Inspect
DIMMs.
No memory detected in the
system.
Install memory or reseat
the memory modules. See
E2011 Memory
configuration
failure.
Check DIMMs.
Memory detected, but is not
configurable. Error detected
during memory
configuration.
E2012 Memory
configured
but unusable.
Check DIMMs.
Memory configured, but is
unusable.
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
The system BIOS failed to
copy its flash image into
memory.
E2014 CMOS RAM
failure.
Power cycle
AC.
CMOS failure. CMOS RAM
not functioning properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E2015 DMA
Controller
failure.
Power cycle
AC.
DMA controller failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E2016 Interrupt
Controller
failure.
Power cycle
AC.
Interrupt controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
Code
Text
Causes
Corrective Actions
book.book Page 34 Thursday, June 3, 2010 4:35 PM