About Your System
Thermal sensor
not detected on
x.
A memory module without a
thermal sensor is installed in
the specified memory slot.
Replace the memory
module. See "System
Time-of-day
clock stopped.
Faulty battery or faulty chip. See "Troubleshooting the
Time-of-day not
set - please run
SETUP program.
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
page 51. If the problem
persists, replace the system
battery. See "System Battery"
Timer chip
counter 2 failed.
Faulty system board.
TPM
configuration
operation
honored. System
will now reset.
A TPM configuration
command has been entered.
The system will reboot and
execute the command.
Information only.
TPM
configuration
operation is
pending. Press
(I) to Ignore OR
(M) to Modify to
allow this change
and reset the
system.
WARNING:
Modifying could
prevent
security.
This message displays during
system restart after a TPM
configuration command has
been entered. User
interaction is required to
proceed.
Enter I or M to proceed.
TPM failure.
A Trusted Platform Module
(TPM) function has failed.
Table 1-2. System Messages
(continued)
Message
Causes
Corrective Actions