Dell DX6004S User Manual
Page 27

About Your System
27
E1624 Lost power
supply
redundancy.
Check PSU
cables.
The power supply
subsystem is no longer
redundant. If the
remaining power supply
fails, the system will
shut down.
E1626 Power Supply
Mismatch. PSU1
= ### W, PSU2
= ### W.
The power supplies in
the system are not the
same wattage.
Ensure that power
supplies with matching
wattage are installed.
See the Technical
Specifications outlined in
your system’s Getting
Started Guide.
E1629 Power required
> PSU wattage.
Check PSU and
config.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
E1710 I/O channel
check error.
Review & clear
SEL.
The system BIOS has
reported an I/O channel
check.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
Table 1-1. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book.book Page 27 Tuesday, September 7, 2010 8:45 PM