Dell DX6004S User Manual
Page 29
About Your System
29
E1810 Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
E1812 Hard drive ##
removed. Check
drive.
The specified hard
drive has been removed
from the system.
Information only.
E1920 iDRAC6 Upgrade
Failed.
optional iDRAC6
upgrade has failed.
E1A14 SAS cable A
failure. Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
E1A15 SAS cable B
failure. Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
E1A1D Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
E2010 Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules. See
E2011 Memory
configuration
failure.
Check DIMMs.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
Table 1-1. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book.book Page 29 Tuesday, September 7, 2010 8:45 PM