Dell DX6004S User Manual
Page 39

About Your System
39
Invalid PCIe card
found in the
Internal_Storage
slot!
The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage controller
slot.
Remove the PCIe expansion
card and install the
integrated storage controller
in the dedicated slot. See
Keyboard fuse has
failed.
Overcurrent detected at the
keyboard connector.
Local keyboard
may not work
because all user
accessible USB
ports are
disabled.
If operating
locally, power
cycle the system
and enter system
setup program to
change settings.
The USB ports are disabled
in the system BIOS.
Power down and restart the
system from the power
button, and then enter the
System Setup program to
enable the USB port(s).
Manufacturing
mode detected.
System is in manufacturing
mode.
Reboot to take the system
out of manufacturing mode.
Maximum rank
count exceeded.
The following
DIMM has been
disabled: x.
Invalid memory
configuration. The system
will run but with the
specified memory module
disabled.
Ensure that the memory
modules are installed in a
valid configuration. See
Memory
Initialization
Warning: Memory
size may be
reduced.
Invalid memory
configuration. The system
will run but with less memory
than is physically available.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Table 1-2. System Messages
(continued)
Message
Causes
Corrective Actions
book.book.book Page 39 Tuesday, September 7, 2010 8:45 PM