Error Code
Message Information
Action
If unintended, verify drive installation. Remove and re-seat
the indicated disk. If the issue persists, see
PDR1001
Message
Fault detected on drive <number> in disk drive bay <bay>.
LCD Message
Fault detected on drive <number> in disk drive bay <bay>.
Check drive.
Details
The controller detected a failure on the disk and has taken
the disk offline.
Action
Re-seat the failed drive. If the issue persists, see
.
PDR1002
Message
A predictive failure detected on drive <number> in disk drive
bay<bay>.
Details
The controller received a SMART error from the drive. The
drive is operational but needs replacement.
Action
The drive will need replacement at the next service window.
PDR1016
Message
Drive <number> is removed from disk drive bay <bay>.
LCD Message
Drive <number> removed from disk drive bay <bay>. Check
drive.
Details
The controller detected that the drive was removed.
Action
Verify drive installation. Re-seat the failed drive. If the issue
persists, see
PDR1024
Message
Drive mismatch detected for drive <number> in disk drive
bay <bay>.
LCD Message
Drive mismatch detected for drive <number> in bay <bay>.
Install correct drive type.
Details
The installed disk does not meet the array requirements, for
example a SATA disk may not operate in an array containing
SAS drives.
Action
Verify that the disk meets the array requirements.
PST0128
Message
No memory is detected.
LCD Message
No memory is detected. Inspect memory devices.
Details
System BIOS was unable to detect memory in the system .