Dell PowerEdge VRTX User Manual
Page 106

Error Code
Message Information
Action
Check presence, reinstall or reconnect, then reattempt the
update. If the issue persists, see
.
HWC4015
Message
Link Tuning error detected.
Details
CMC has old firmware. After updating the firmware the CMC
will recognize the device.
Action
Update the CMC firmware. If the issue persists, see
.
HWC5001
Message
<name> is offline.
Action
If unexpected, check presence, then reinstall or reconnect.
HWC5002
Message
A fabric mismatch detected on <name>.
Details
The fabric type for the IOM and PCIe mezzanine cards must
match.
Action
Check chassis fabric type in CMC GUI and compare to the
type of IOM or PCIe mezzanine card.
HWC5004
Message
A link tuning failure detected on <name>.
Details
CMC has old firmware. After updating the firmware the CMC
will recognize the device.
Action
Update the CMC firmware. If the issue persists, see
.
HWC5006
Message
A failure is detected on <name>.
Action
.
HWC5008
Message
Console is not available for the <name>.
Action
.
HWC5010
Message
<name> cannot detect any hosts.
Action
.
HWC5014
Message
<name> is not functional and is powered off.
Action
.