Error Code
Message Information
TMP0104
Message
The system board <name> temperature is outside of range.
LCD Message
System board <name> temperature is outside of range.
Details
Ambient air temperature is too warm or cool.
Action
The system board <name> temperature is outside of the
optimum range. Check Fans.
TMP0106
Message
The memory module <number> temperature is less than the
lower warning threshold.
LCD Message
Memory module <number> temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0107
Message
The memory module <number> temperature is less than the
lower critical threshold.
LCD Message
Memory module <number> temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0108
Message
The memory module <number> temperature is greater than
the upper warning threshold.
LCD Message
Memory module <number> temperature is outside of range.
Check Fans.
Details
Ambient air temperature is too warm or one or more fans
may have failed.
Action
The system board <name> temperature is outside of the
optimum range. Check Fans.
TMP0109
Message
The memory module <number> temperature is greater than
the upper critical threshold.
LCD Message
Memory module <number> temperature is outside of range.
Check Fans.
Details
Ambient air temperature is too warm or one or more fans
may have failed.
Action
The system board <name> temperature is outside of the
optimum range. Check Fans.