Error Code
Message Information
SEC0031
Message
The chassis is open while the power is on.
LCD Message
Intrusion detected. Check chassis cover.
Details
The chassis is open. System performance may be degraded,
and security may be compromised.
Action
Close the chassis. Check system logs.
SEC0033
Message
The chassis is open while the power is off.
LCD Message
Intrusion detected. Check chassis cover.
Details
The chassis was opened while the power was off. System
security may have been comprised.
Action
Close the chassis and verify hardware inventory. Check
system logs.
SEC0040
Message
A critical stop occurred during OS load.
Details
Operating system generated critical stop IPMI event. (Sensor
type code = 20H)
Action
Check video and operating system logs for additional
information
SEC0041
Message
BIOS detected an error configuring the Intel Trusted
Execution Technology (TXT).
LCD Message
BIOS detected an error configuring TXT. Check system
configuration.
Details
TXT initialization failure. System configuration may have
changed.
Action
Check system hardware inventory and software
configuration.
SEC0042
Message
Processor detected an error while performing an Intel
Trusted Execution Technology (TXT) operation.
LCD Message
CPU detected an error while performing a TXT operation.
Check system configuration.
Details
TXT CPU microcode boot failure. System configuration may
have changed.
Action
Check system hardware inventory and software
configuration.