Dell PowerEdge VRTX User Manual
Page 119

Error Code
Message Information
PCI2002
Message
A fatal IO error detected on a component at slot <number>.
LCD Message
Fatal IO error on slot <number>.
Details
System performance may be degraded, or system may fail to
operate.
Action
Cycle input power, update component drivers, remove and
reinstall the device.
PCI3000
Message
Device option ROM on embedded NIC failed to support Link
Tuning or FlexAddress.
Details
Either the BIOS, BMC/iDRAC, or LOM firmware is out of date
and does not support FlexAddress.
Action
Update BIOS, BMC/iDRAC, and LOM firmware. If the issue
persists, see
PCI3002
Message
Failed to program virtual MAC address on a component at
bus <bus>device<device>function <func>.
Details
Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of
date and does not support FlexAddress.
Action
Update BIOS, BMC/iDRAC, LOM, and PCIe mezzanine card
firmware. If the issue persists, see
PCI3004
Message
Device option ROM on PCIe mezzanine card <number>
failed to support Link Tuning or FlexAddress.
Details
Either the BIOS, BMC/iDRAC, or PCIe mezzanine card
firmware is out of date and does not support FlexAddress.
Action
Update BIOS, BMC/iDRAC, and PCIe mezzanine card
firmware. If the issue persists, see
PCI3006
Message
Failed to get Link Tuning or FlexAddress data from iDRAC.
Details
Either the BIOS or BMC/iDRAC firmware is out of date and
does not support FlexAddress.
Action
Update BIOS, and BMC/iDRAC firmware. If the issue persists,
see
PCI3008
Message
A non-fatal PCIe error detected on a component at bus
<bus>device<device>function <func>.
Details
System performance may be degraded.
119