Error Code
Message Information
CPU0010
Message
CPU <number> is throttled.
Details
The CPU is throttled due to thermal or power conditions.
Action
Review system logs for power or thermal exceptions.
CPU0023
Message
CPU <number> is absent.
LCD Message
CPU <number> is absent. Check CPU.
Action
Verify processor installation. If present, re-seat the
processor.
CPU0100
Message
CPU <number> temperature is less than the lower warning
threshold.
Details
System performance may be degraded.
Action
Check system operating environment.
CPU0101
Message
CPU <number> temperature is less than the lower critical
threshold.
LCD Message
CPU <number> temperature is outside of range.
Details
System performance may be degraded.
Action
Check system operating environment, fans, and heat-sinks.
CPU0102
Message
CPU <number> temperature is greater than the upper
warning threshold.
Details
System performance may be degraded.
Action
Check system operating environment, fans, and heat-sinks.
CPU0103
Message
CPU <number> temperature is greater than the upper critical
threshold.
LCD Message
CPU <number> temperature is outside of range. Check fans.
Details
System performance may be degraded.
Action
Check system operating environment, fans, and heat-sinks.
CPU0104
Message
CPU <number> temperature is outside of range.
LCD Message
CPU <number> temperature is outside of range. Check fans.
Details
System performance may be degraded.
97