Error Code
Message Information
Action
Re-seat the memory modules. If the issue persists, see
.
PST0129
Message
Memory is detected, but is not configurable.
LCD Message
Memory is detected, but is not configurable. Check memory
devices.
Details
System BIOS detected memory, but was unable to configure
the memory for system operation.
Action
Compare system memory installation to supported system
memory configurations.
PST0130
Message
Memory is configured, but not usable.
LCD Message
Memory is configured, but not usable. Check memory
devices
Details
The system BIOS encountered device failures or speed
configurations that resulted in unused memory.
Action
Re-seat the memory modules. If the issue persists, see
.
PST0131
Message
System BIOS shadow failed.
LCD Message
System BIOS shadow failed. Check memory devices.
Details
Memory errors occurred copying BIOS image into system
memory.
Action
Remove input power. Reduce system memory to minimum
configuration and apply input power.
PST0132
Message
CMOS failed.
LCD Message
CMOS failed. Power cycle system.
Details
System BIOS detected a failure with CMOS memory during
system POST.
Action
Check system event log for CMOS battery exceptions.
Remove and reapply input power. If the issue persists, see
.
PST0133
Message
DMA controller failed.
LCD Message
DMA controller failed. Power cycle system.