Error Code
Message Information
Details
PXE is one way to boot a system from the network.
Action
Check the network and PXE server configuration.
SEL1306
Message
Invalid boot sector found.
Details
The disk in the drive is not formatted correctly or does not
contain the necessary operating system files.
Action
Replace diskette with a bootable disk.
SEL1308
Message
A time-out occurred while waiting for user to select a boot
source.
Details
The system has failed to boot to an operating system and
needs the user to select a boot source.
Action
Select boot source within the time allowed.
SEL1501
Message
Chassis management controller (CMC) redundancy is lost.
Details
An action or failure has taken place that breaks CMC
redundancy.
Action
Check the CMC network cables and network connections.
Check that CMC firmware versions match.
SEL1502
Message
Chassis management controller (CMC) redundancy is
degraded.
Details
An action or failure has taken place that breaks CMC
redundancy.
Action
Check the CMC network cables and network connections.
Check that CMC firmware versions match.
SEL1504
Message
The chassis management controller (CMC) is not redundant.
Insufficient resources to maintain normal operations.
Details
There is not enough available power for two CMC's to
operate.
Action
Check the overall power consumption and power status.
SEL1506
Message
Lost communications with Chassis Group Member
<number>.
Details
The primary CMC has lost communication with the indicated
member CMC.
139