Dell PowerEdge VRTX User Manual
Page 94

Error Code
Message Information
Action
Allow the battery to charge. If the issue persists, see
.
BAT0007
Message
The storage battery has failed.
LCD Message
The storage battery has failed. Check battery.
Details
Verify the cable connection between the storage battery and
the controller.
Action
Verify the storage battery installation.
BAT0010
Message
The storage battery for disk drive bay <bay> is low.
Details
System has to remain powered on to charge the storage
battery.
Action
Allow the storage battery to charge. If the issue persists, see
.
BAT0012
Message
The storage battery for disk drive bay <bay> has failed.
LCD Message
Battery for disk drive bay <bay> has failed. Check battery.
Details
Verify the cable connection between the storage battery and
the controller.
Action
Verify the storage battery installation.
BAT0014
Message
The storage battery for disk drive bay <bay> is absent.
LCD Message
Battery for disk drive bay <bay> is absent. Check battery.
Details
Verify the cable connection between the storage battery and
the controller.
Action
Verify the storage battery installation.
BAT0015
Message
The <name> battery is low.
Details
The low <name> battery may impact system performance
negatively.
Action
Recharge the <name> battery if possible. If the problem
continues replace the <name> battery.
BAT0017
Message
The <name> battery has failed.
LCD Message
The <name> battery has failed. Check battery.
94