Dell PowerEdge VRTX User Manual
Page 129

Error Code
Message Information
LCD Message
PSU redundancy degraded. Check PSU cables.
Details
The current power operational mode is non-redundant
because of a power supply exception, a power supply
inventory change, or a system power inventory change.
Action
Check the event log for power supply failures. Review
system configuration and power consumption.
PWR1001
Message
The system performance was degraded.
LCD Message
System performance degraded. Check PSUs and system
configuration.
Details
To avoid shutdown, system performance has been degraded.
Action
Review system configuration and system logs for thermal or
environmental failures and warnings.
PWR1002
Message
The system performance degraded because of thermal
protection.
Details
To avoid shutdown, system performance has been degraded.
Action
Review system configuration and system logs for thermal or
environmental failures and warnings.
PWR1003
Message
The system performance degraded because cooling capacity
has changed.
Details
The current power supply configuration does not meet the
platform requirements to enable redundancy. If a power
supply fails the system may shutdown.
Action
If unintended, review system configuration and power
consumption and install power supplies accordingly. Check
power supply status for failures.
PWR1004
Message
The system performance degraded because power capacity
has changed.
Details
The system may power down or operate in a performance
degraded state.
Action
Check the event log for power supply failures. Review
system configuration and power consumption and upgrade
or install power supplies accordingly.
PWR1005
Message
The system performance degraded because the user-
defined power capacity has changed.
129