Dell PowerEdge VRTX User Manual
Page 133

Error Code
Message Information
RFM1203
Message
Internal Dual SD Module is not redundant.
Details
Internal Dual SD Module is not redundant.
Action
Install additional SD card and configure for redundancy if
redundancy is desired.
RFM1205
Message
Internal Dual SD Module is not redundant. Insufficient
resources to maintain normal operations.
LCD Message
Internal Dual SD Module is not redundant. Insufficient
resources. Check SD Card.
Details
The current operating configuration cannot maintain
redundancy. The unit may operate in a degraded state.
Action
Review this manual and SD card configuration.
RFM2001
Message
Internal Dual SD Module <name> is absent.
LCD Message
Internal Dual SD Module <name> is absent. Check SD Card.
Details
The SD card module is not detected or not installed.
Action
If unintended, reinstall the SD module.
RFM2002
Message
Internal Dual SD Module <name> is offline.
Details
The SD card module is installed but may be improperly
installed or configured incorrectly.
Action
Reinstall the SD module.
RFM2004
Message
Failure detected on Internal Dual SD Module <name>.
LCD Message
Internal Dual SD Module <name> failed. Check SD Card.
Details
The SD card module is installed but improperly configured or
failed to initialize.
Action
Reinstall the SD module and remove and reinstall SD cards.
RFM2006
Message
Internal Dual SD Module <name> is write protected.
Details
The module is write-protected. Changes may not be written
to the media.
Action
If unintended, remove the media and disable write
protection.
133