Error Code
Message Information
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0005
Message
Persistent correctable memory error limit reached for a
memory device at location(s) <location>.
LCD Message
Persistent correctable memory error limit reached for
<location>. Re-seat memory.
Details
The memory is operational. This an early indicator of a
possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0007
Message
Unsupported memory configuration; check memory device
at location <location>.
LCD Message
Unsupported memory configuration. Check memory
<location>.
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
MEM0009
Message
Memory device at location <location> is throttled.
Details
System performance is degraded.
Action
If unexpected, review system logs for power or thermal
exceptions.
MEM0010
Message
Memory device at location <location> is over heating.
LCD Message
Memory device <location> is over heating. Check fans.
Details
System performance is degraded.
Action
If unexpected, review system logs for power or thermal
exceptions.
MEM0022
Message
Memory device at location <location> is absent.
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
110