Parameter ID
26
Parameter
Name
Raster Scan Time
Data
Scan Time (Unit: See Explanation.)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This command is used to set the raster scan time (operation by command).
The scan time is the set value × 10 μs.
E.g. For the interval of 100 ms, set 10000 (10000 × 10 μs = 100 ms).
Related
Command
/Parameter
Raster Scan Duty Ratio (Parameter ID = 27)
Raster Scan Angle (Parameter ID = 28)
Raster Scan Interval Time (Parameter ID = 30)
Raster Scan Start Position (Parameter ID = 31)
Parameter ID
27
Parameter
Name
Raster Scan Duty Ratio
Data
Raster scan duty ratio (Unit: %)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the duty ratio of raster scan (operation by command).
(See Explanation of Parameter ID = 26.)
Related
Command
/Parameter
Raster Scan Time (Parameter ID = 26)
Raster Scan Angle (Parameter ID = 28)
Raster Scan Interval Time (Parameter ID = 30)
Raster Scan Start Position (Parameter ID = 31)