Parameter ID
15
Parameter
Name
High-speed Serial Communication
Offset
Data
High-speed Serial Communication Offset (Unit: pulse)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
Set this parameter, when a center position of the high-speed serial communications
data is offset.
This is effective, when operating by high-speed serial communications.
0 is set usually.
E.g. Data = 100
High-speed serial communication data(16bit) 0x8000 = 100 encoder pulse position.
Related
Command
/Parameter
Parameter ID
16
Parameter
Name
First Digital Notch Filter Central
Frequency
Data
Central frequency of the first digital notch filter (Unit: Hz)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the central frequency of the first digital notch filter.
Related
Command
/Parameter
First Digital Notch Filter Q Value (Parameter ID = 17)
First Digital Notch Filter Depth (Parameter ID = 18)
Parameter ID
17
Parameter
Name
First Digital Notch Filter Q Value
Data
Q value of the first digital notch filter (Unit: ×100)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the Q value of the first digital notch filter.
Set a value multiplied by 100.
Related
Command
/Parameter
First Digital Notch Filter Central Frequency (Parameter ID = 16)