Command ID

12

Command

Name

Current Position Read

Data

0: Current position
1: Current target value (Program origin)
2: Current target value (Absolute position)

Return

Value

Position (Pulse)

Explanation

Command ID = 30: Program Coordinate System

Command ID

13

Command

Name

Version Read

Data

0: Main DSP
1: Sub DSP

Return

Value

Ver. No

Explanation

Command ID

14

Command

Name

Status Read

Data

-

Return

Value

Status (16 bits)

Explanation

Each status can be checked by each bit after conversion into 16-bit display.

Bit Abbreviation

Meaning

Hex

Format

0 SRVON

Servo

ON

0x0001

1 SYNC

Counter 0-position confirmed

0x0002

2 INPOS

Settlement in in-position range

0x0004

3 ALARM

Error

0x0008

4 ORGN

Homing to origin

0x0010

5 PROG

Program coordinate setting

0x0020

6

7

8 MOVE

Moving (including scan)

0x0100

9 CMODE

Control mode 0 : PI

1 : LQ

0x0200

10 WARN

Encoder signal warning

0x0400

11

12 TARGET

Target

position 0:Absolute position

1:Relative position

0x1000

13 ACC

Acceleration control 0 : OFF
1 : ON

0x2000

14 SETPOS

Target position set

0x4000

15

Note: Return value of the command is a decimal number.