56
Command ID
12
Command
Name
Current Position Read
Data
0: Current position
1: Current target value (Program origin)
2: Current target value (Absolute position)
Return
Value
Position (Pulse)
Explanation
Command ID = 30: Program Coordinate System
Command ID
13
Command
Name
Version Read
Data
0: Main DSP
1: Sub DSP
Return
Value
Ver. No
Explanation
Command ID
14
Command
Name
Status Read
Data
-
Return
Value
Status (16 bits)
Explanation
Each status can be checked by each bit after conversion into 16-bit display.
Bit Abbreviation
Meaning
Hex
Format
0 SRVON
Servo
ON
0x0001
1 SYNC
Counter 0-position confirmed
0x0002
2 INPOS
Settlement in in-position range
0x0004
3 ALARM
Error
0x0008
4 ORGN
Homing to origin
0x0010
5 PROG
Program coordinate setting
0x0020
6
7
8 MOVE
Moving (including scan)
0x0100
9 CMODE
Control mode 0 : PI
1 : LQ
0x0200
10 WARN
Encoder signal warning
0x0400
11
12 TARGET
Target
position 0:Absolute position
1:Relative position
0x1000
13 ACC
Acceleration control 0 : OFF
1 : ON
0x2000
14 SETPOS
Target position set
0x4000
15
Note: Return value of the command is a decimal number.