beautypg.com

Monitor output and digital input functions – Canon GALVANO GC-251 User Manual

Page 39

background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

39

5. Monitor Output and Digital Input Functions

The controller has an analog monitor output connector for monitoring the operation status and a

digital I/O connector for external signal input.

5.1.

Connector Pin Arrangement

The controller is equipped with the following:

Analog monitor output connector ×1

Digital I/O connector ×1

The monitor board for the evaluation that can do the analog output signal confirmation and the I/O of

a digital signal is prepared as an optional product. Please contact the Sales Department.

Analog monitor output

connector

Digital I/O

connector

Monitor Board for

evaluation