2.7.1 RS-232C command input

RS-232C command input allows the following:

• Operation

setting

• Parameter

setting

• Error

processing

• Status

check

(For details, see 7, “Commands.”)

If position data send by high-speed serial communication is disabled, RS-232C command input is

enough for the following:

• Step

movement

• Raster

scan

(Continuous

oscillation of a certain angle at a fixed frequency)

(Communication specifications)

Wiring Cross

wiring

Communication rate

38400 bps

Data length

8 bits

Stop bit

1

Parity None

Data format

ASCII code

Delimiter code

LF (0x0a) or CR (0x0d)