Canon GALVANO GC-251 User Manual
Page 22

CANON Digital Galvano Scanner System
KP-1SM Series + GC-251
Users Manual 1.00
22
(Target Position Data)
XDAT
YDAT
The data length of the target position data by the high-speed serial communication can be
changed by two following parameters.
The target position data length can be changed in 16bit – 20bit.
Parameter ID
DATA
16
16bit Data
17
17bit Data
18
18bit Data
19
19bit Data
20
20bit Data
The least significant bit position of the target position data of high-speed serial communication
20bit data can be set by following parameter.
The right shifts this number of bit make the target position data.
Parameter ID
DATA
0
0bit position
1
1bit position
2
2bit position
3
3bit position
4
4bit position
An example of the setting as follows.
Parameter ID = 67 16
Parameter ID = 68 1
Parameter ID = 67 18
Parameter ID = 68 2