CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

57

Command ID

15

Command

Name

Error Read

Data

-

Return

Value

Error (16 bits)

Explanation

Each status can be checked by each bit after conversion into 16-bit display.
For details about errors, see 9-2, “Errors.”

Bit Abbreviation

Meaning

Hex

Format

0 STRK

Stroke

over

0x0001

1 CNT

Counter

over

0x0002

2 INP

In-position

overtime

0x0004

3 SRV

No

clock

0x0008

4 CUR

Driver

overheat

0x0010

5 HOT

Motor

overheat

0x0020

6 FOM

Format

error

0x0040

7 COM

Command data error

0x0080

8 PAR

Parameter

error

0x0100

9 STA

Status

error

0x0200

10 TRN

Communication

error

0x0400

11 ORG

Homing

error

0x0800

12 ENC

Encoder signal error

0x1000

13 OTP

Out-position

error

0x2000

14 CMPER

Servo OFF by hardware

0x4000

15 ETC

Current

saturation

0x8000


Command ID

18

Command

Name

Acceleration Control

Data

0: OFF
1: ON

Return

Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

This command cannot be used now.

Command ID

20

Command

Name

Target Position Setting

Data

Target position (Pulse)

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

This command is used to set a target position by step movement.

Related
Command

Step movement procedure

Command ID = 10: Target Value Setting Mode

Command ID = 20: Target Position Setting

Command ID = 8 Data = 0: Step Movement Start