beautypg.com

Canon GALVANO GC-251 User Manual

Page 58

background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

58

Command ID

22

Command

Name

Target Velocity Setting

Data

Target velocity (Unit: pulse/s)

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

This command is used to set the maximum velocity of step movement.
The velocity cannot be higher than “Parameter ID = 2: Maximum velocity.”
If this command is not set, the velocity specified by “Parameter ID = 2: Maximum
velocity” is used.

Related
Command

Step movement procedure
Command ID = 22 Target Velocity Setting

Command ID = 10: Target Value Setting Mode

Command ID = 20: Target Position Setting

Command ID = 8 Data = 0: Movement Start