Canon GALVANO GC-251 User Manual
Page 48
CANON Digital Galvano Scanner System
KP-1SM Series + GC-251
Users Manual 1.00
48
6.2.
Operation that synchronizes with external trigger Signal input(Raster Scan)
“4-3. raster scan operation”, It can be operated synchronizing with external trigger Signal.
The Movement Pattern
There are two kinds of movement patterns.
The raster scan of one coming and going operates whenever the external trigger signal is input.
The raster scan of one way operates whenever the external trigger signal is input.
and operation pattern can be selected by RS-232C command (Command ID = 23 ‘ Operation
Mode setting ‘)
External Trigger Signal
Raster Scan position
(Current Angle Position)
Angle
Voltage
External Trigger Signal
Raster Scan position
(Current Angle Position)
Angle
Voltage