Command ID

26

Command

Name

Parameter Value Check

Data

Parameter ID

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

This command returns the parameter setting of Parameter ID.

Command ID

30

Command

Name

Program Coordinate System

Data

0: Z phase
1: Program Origin

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

For a raster scan, the center of the oscillation angle can be changed.
0: Z phase

Set the Z-phase position as the center. This setting is in the default after activation.

1: Program Origin

Set the current position as the center.
When setting the program origin, move once to the desired center and then specify the
position by this command.

Command ID

40

Command

Name

Monitor Output Selection (A2, A8)

Data

0: Encoder Head1 A phase
1: Encoder Head2 A phase
2: Corrected A phase
3: Position error

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

The output signal of analog monitor output A2 (the Axis1) and A8 (the Axis2) can be
selected.
When the controller starts, the 3: Position error has been selected.
(For details, see 5.2, “Analog Monitor Output Selecting ”)

Related
Command

Command ID = 44: Monitor Magnification Setting (A2, A8 )